BIOLOGICAL SAFEY CABINET CLASS I-II-III - Email ; [email protected]
The Class II Biological Safety Cabinet is designed with inward air flow at a velocity to protect personnel, HEPA-filtered vertical laminar airflow for product protection, and HEPA-filtered exhausted air for environmental protection.
Conform ;
1.US Standard ANSI/NSF
2.European Standard EN
3.Chinese Standard YY
Airflow System:
- 30% air recirculation
- 70% air exhaust
- Maintain a minimum average inflow velocity is 0.65 m/s and average downflow velocity is 0.37 m/s
External Size (mm):1100*850*2200
Internal Size (mm):970*600*660
Main Filter: HEPA (one piece)
Filtration Performance: 99.999% (0.3 microns)
Exhaust filter: HEPA filter
Filtration Performance: 99.999% (0.3 microns)
Inflow Velocity: 0.65m/s±0.015m/s
Down Flow Velocity: 0.37m/s±0.015m/s
Air Circulation: 30%
Exhaust Air: 70%
Control System: Microprocessor
Front Panel: Multi-layer doubling toughened glass
Lighting: 800Lux ~ 1100Lux
Noise: <65dB
Clean Level: Class 100
Rated Voltage: 110V~240V/50Hz~60Hz (OPTIONAL)
Power: 800W
Collecting: >4000ml. Fitted with draining valve
Vibration: the net displace is no more than 5rms, when the frequency is from10Hz to 10Hz
Material: Type 304 stainless steel for working zone interior
Stability: the core part can stand 23kg pressure without permanent distortion
Biosafety: Personnel safety: Hammer blow samples<10CFU/time Slit Samples<5CFU/time
Product safety: the microorganism germ falls<5CFU/time
Cross infection safety: the microorganism germ falls<2CGU/time
Products Features
● Advanced Microprocessor Control System. The control system measures the air flow pressure accurately and balances the air velocity strictly for entire working chamber. An unique advanced here is that a strip bar on the LED control panel works as an indicator of the life utility of the main filter and exhaust filter, which reminds the user to replace the HEPA filters on time so as to provide special protection for operators.
● Intelligent Filter Compensation System. The vertical airflow will be automatically supplied at the speed of 0.37m/s±0.015m/s without interruption. When filter block occurs, the fan motor will increase its speed to ensure constant vertical air flow to guarantee the safe performance.
● HEPA Filter. 99.999% efficient (0.3 microns) .It’s constructed of pleated borosilicate glass fibers.
● The motor drive front window can be moved smoothly and exactly to desirable position, and it can be completely closed when not use, providing a physical barrier
● Easy to Decontaminate and Disinfect. The working chamber of the safety cabinet is easy to be cleaned and disinfected. The stainless steel counter surface can be taken for autoclaving. UV light can only be turned on when the front window is closed completely and the fluorescent lamp is turned off. It avoids the potential
MTC-81100IIA2-X
Multron Top
Jalan Mulia IV Blok M-X
No. 9 Cipondoh Makmur
Tel. 021-26237478
Fax. 021-5544863
E-mail ; [email protected]
Http://www.alatlaboratorium.org
Berhati-hatilah dalam bertransaksi, pastikan anda membaca Tips Aman Berbelanja sebelum bertransaksi.
Nama
Alatlaboratorium.org Indonesia
Telepon
021-26327478 0815- 9321798 0813-85999849
Lokasi
Banten